Reusable packaging can cut disposable waste, but each trip through a washing or refill system carries an operational energy cost. Heating water, running pumps and drying containers all contribute to the energy footprint of reuse. For operations teams, reducing that footprint starts with locating the largest loads, then identifying where recovery technologies or equipment controls could reduce demand.
Finding Where the Energy Footprint Begins
A useful energy assessment follows the water through the operation. In bottle washing and food service warewashing, that means separating the energy used to heat water from the electricity needed to circulate it. Drying warrants its own assessment, including whether the process relies on ambient air or powered equipment.
Teams can reduce drying energy by matching air movement, temperature and drying time to actual throughput rather than running powered drying equipment at a fixed setting. These distinctions help teams identify which changes could affect their largest loads.
ENERGY STAR illustrates the scale of washing costs by comparing the energy use of efficient commercial dishwashing models. It notes that a conventional machine “uses about $3,750/year in water and energy,” versus $2,250 for a certified model. The $1,500 difference combines both utilities, so it shouldn’t be read as an energy-only saving.
The connection between those costs matters. Every gallon of hot water avoided also avoids the energy needed to heat its replacement. Where hot water remains necessary, recovering heat before discharge offers another opportunity.
Cutting Water Heating Costs in Washing Systems
Heat recovery reduces the temperature lift a heater must provide. In a high-temperature dishwasher, transferring heat from outgoing wastewater to incoming water can reduce the load on the booster heater supplying the sanitizing rinse.
Commercial dishwasher manufacturer Hobart says its Drain Water Energy Recovery system “captures the heat from hot wastewater,” using it to preheat incoming water to up to 110° Fahrenheit before the booster heater completes the sanitizing rinse. That reduces the booster heater’s work to reach the 180° Fahrenheit sanitizing rinse temperature.
The exchange also cools discharge below 140° Fahrenheit, avoiding the cold water that conventional drain-water tempering adds solely for cooling. Both effects reduce utility demand during operation.
When weighing retrofitting versus replacement, operators should first ask the manufacturer whether their existing machine can accommodate heat recovery. Installed costs and expected savings can then inform the decision alongside the machine’s remaining service life.
Reducing Fresh Water Demand Through Water Recovery
Heat recovery captures energy from water leaving a process. Water recovery, on the other hand, addresses whether some of that water can return to useful service. For a washing or refill operation, the assessment should identify a suitable reuse point and the treatment needed to reach it.
MECO, a Grundfos Company and an industrial water purification and reuse provider, says smart analytics helps users “minimize [their] water footprint by maximizing [their] pure water recovery.” According to the company, increasing recovery reduces the raw feedwater required and the volume discharged.
This makes water recovery a useful consideration alongside heat recovery when assessing resource demand. Those recovery metrics can also inform the retrofitting-versus-replacement decision by showing whether targeted upgrades could reduce utility demand before a full system replacement is considered.
Reusable-packaging operator Bold Reuse provides a practical example of reduced consumption. Sports Business Journal reports that the company had cut its water use by 50% in the year before April 2024, according to co-founder Heather Watkins. Its roughly 10,000-square-foot Portland, Ore., wash facility used 5,000-10,000 gallons monthly, about a restaurant’s daily consumption. Watkins expected efficiency to improve further with volume.
When it comes to sustainable technology integration, water savings and energy savings need separate evaluation. The energy balance should include any additional pumping or treatment, as well as any reheating avoided.
Catching Energy Waste Through Monitoring and Controls
Recovery equipment addresses identifiable losses, but operating data helps reveal when a system uses more energy than the process requires. A useful review compares consumption during production with idle periods, then investigates whether equipment settings match actual demand.
Drive and controls manufacturer Danfoss explains why speed control over throttling can reduce pumping demand. For suitable centrifugal pumps and fans, power follows the cube of speed. Danfoss explains that “a drive system running at half speed” consumes only 12.5% of rated power, while throttling flow produces a much smaller power reduction.
That relationship isn’t a site-level savings forecast. Danfoss cautions that speed changes also alter the operating point and efficiency, and some equipment is unsuitable for speed control. Teams therefore need to evaluate the actual application before selecting a drive or changing its settings.
Building a Smarter Energy Profile for Reuse Systems
The most cost-effective way to upgrade an existing water treatment system depends on where it loses resources and which changes the equipment can accommodate. A targeted recovery or controls retrofit should be compared with replacement, using installed costs and expected savings under actual operating conditions.
Treating energy management as an ongoing part of the reuse strategy gives teams a basis for choosing improvements and checking whether those improvements deliver results.


2 Comments